Lumen [lm] - is a measure of the luminous flux in the SI system. Luminous flux determines the amount of light emitted from the light source. Otherwise, it is the total amount of light emitted by a particular light source. The value of the luminous flux for a lamp or lamps can be read from the package or card catalog.

 
Lampa przemysłowa LED 85Watt - Strumień świetny, skuteczność świetlna.


Luminance [nt] - The unit of luminance is  1 candela per square meter [cd / m2] referred to as nit [nt]. Luminance is a measure of the intensity of  light in a given direction. It determines if a visual sensation is perceived by the eye from a lit surface. Using standard bulbs or LED bulbs this parameter is rarely used.
 
Color Temperature [K] - The color temperature is measured in degrees Kelvin [K] and determines the color impression of light emitted by a given light bulb. The light emitted by a candle is a temperature of about 2000 [K], a halogen bulb has a  color of about 2700 [K],  daylight white colour is around 4000-5000 [K], cold white light is in the range above 5000 [K]. Light with a color temperature 2800-3200 [K] is warmer and promotes relaxation and resting, much like sunlight at sunrise and sunset. Cold white light range above 5000 [K] is the most suitable for the working applications, is a stimulant and is  similar to daylight at noon.



Lampa przemysłowa LED 85Watt - Parametry koloru CCT
 
 
 
Color rendering index Ra,. CRI Colour Rendering Index. This factor determines the degree of fidelity color rendering characterized by a light source. The scope of this factor is 0-100, where 0 is for monochromatic light / one color like red, blue, etc. /. Values greater than zero specify white light. Low pressure sodium lamps have a very low coefficient of about color rendering. Ra = 20, mercury incandescent lamps Ra = 40-50, high-pressure mercury lamps, Ra = 20-65 for example. Our industrial LED fittings such as a series of TL-HBCXA and TL-FLCXA have an Ra> 80. Sunlight is considered as a reference and has a CRI Ra = 100.
 
Lampa przemysłowa LED 85Watt - Współczynnik oddawania barw oraz jego składowe
 
Lux [lx] - is a unit of light intensity in the SI system. Illuminance determines how much luminous flux is falling on a given surface. Illuminance is 1 [lx] if the surface of one square meter 1 [m2] falls 1 luminous flux [lm]. 1 [lx] = 1 [lm] / [m2]. The relevant standards define the required illumination, eg. In the workplace, in offices, in the offices of the production halls etc., this value is given in [lx].



The picture below shows the distribution of light intensity in a warehouse in [lx].
The project uses our Tecoled energy-saving TL-HBCXA5080085-20 R4 High Bays.
This simulation was carried using Dialux software

Oświetlenie przemysłowe led z zastosowaniem lampy przemysłowej LED 85Watt - symulacja wykonana w programie Dialux



The following picture shows a room with a spatial distribution of light intensity.
The industrial lamps used in this project provide uniform distribution of light intensity on the required routes.


Oświetlenie przemysłowe led z zastosowaniem lampy przemysłowej LED 85Watt - symulacja wykonana w programie Dialux
<< read more...