Industrial LED Lamps - research Flir thermal imaging camera.

blog
To ensure long-term reliable operation of LED lighting, should be taken into account when designing luminaires and lamps many factors. One of the most important is the LED temperature, which largely determines the life of the lamp L70.

Too high operating temperature of LEDs leads to a quicker loss of brightness, change in color or color rendering index. To ensure optimal operation of LEDs, use heat sinks heat extraction of specific thermal resistance Rth.
A properly designed heat sink provides heat dissipation of the LEDs to the surrounding air temperature Ta, maintaining nominal junction temperature Tj diodes. Heat sink thermal resistance Rth strategic projections may be calculated using the formula This Tj = + (Rth Ptotal *) + (* Rled Pled).


Rth = (Tj-Ta- (Rled*Pled)) / Ptotal - Rth - thermal resistance of the heat sink [W / K], Ptotal - total power LEDs [Watt] Plaid - the power of a single diode [Watt] Rled - thermal resistance LED [W / K], Tj - junction temperature of the diode [C] Ta - ambient temperature [C]

 
The above image from an infrared camera shows the distribution of temperature  across the diodes.
The image is that of an 85 watt industrial LED light fitting which was operates for 60 minutes
The thermal image shows the highest temperature and the loaction of the warmest point. The highest recorded temperature for this particular diode  is 64.1C.

(Eng.) IES LM-80-2008 test LEDs
 
 
Comparing the results  achieved  with a report for this particular  diode CXA2520 (p.17), we can see that the temperature of the LEDs in this lamp are well below normal recommended paramaters. Dthus the lamps we design here at Tecoled will provide long-term use working under these conditions. Our calculations indicate lifetimes of up to 100,000 hrs.
<< read more...